31 فروردین 1403
شهريار عصفوري

شهریار عصفوری

مرتبه علمی: استاد
نشانی: دانشکده مهندسی نفت، گاز و پتروشیمی - گروه مهندسی شیمی
تحصیلات: دکترای تخصصی / مهندسی شیمی
تلفن: 88019360
دانشکده: دانشکده مهندسی نفت، گاز و پتروشیمی

مشخصات پژوهش

عنوان Application of Photo-Fenton, Electro-Fenton, and Photo-Electro-Fenton processes for the treatment of DMSO and DMAC wastewaters
نوع پژوهش مقالات در نشریات
کلیدواژه‌ها
DMSO wastewater; DMAC wastewater; Photo-Fenton; Electro-Fenton; Photo-Electro-Fenton processes; Advanced Oxidation Process (AOP)
مجله Arabian Journal of Chemistry
شناسه DOI https://doi.org/10.1016/j.arabjc.2022.104229
پژوهشگران مریم بهروزه (نفر اول) ، محمد مهدی پریوژ (نفر دوم) ، دانش الناز (نفر سوم) ، محمد جواد دیانت (نفر چهارم) ، محسن عباسی (نفر پنجم) ، شهریار عصفوری (نفر ششم به بعد) ، امیر رستمی (نفر ششم به بعد) ، میکا سیلانپا (نفر ششم به بعد) ، مهدیه دیباج (نفر ششم به بعد) ، محمد اکرمی (نفر ششم به بعد)

چکیده

Biological treatment, due to the formation of hazardous chemicals to remove organic compounds such as dimethyl sulfoxide (DMSO) and N, N-dimethylacetamide (DMAC), has limited potential. Advanced oxidation processes (AOPs) are regarded as a viable alternative for treating molecules containing carbon-hydrogen bonds that cannot be broken down by traditional physico-chemical methods. In this investigation, various AOPs such as Photo-Fenton, Electro- Fenton, and Photo-Electro-Fenton processes were studied to treat wastewaters containing DMSO and DMAC. The effects of the operating parameters, including various initial concentrations of DMSO and DMAC, initial pH, reaction time, different concentrations of Fenton’s reagent, power of UV lamp, different concentrations of electrolytes, the distance between electrodes and current intensity, were investigated. The findings of the experiments revealed that a pH of 3 and a reaction time of 120 min were optimal. At 2000 mg L-1 of DMSO, maximum degradation and the finalconcentration of TOC were 98.64 % and 256.8 mg L-1, respectively, by the Electro-Fenton process under the optimal conditions. The Electro-Fenton process was successful in determining the maximum degradation of DMAC (96.31 %) and the final TOC concentration (10.03 mg L -1) at250 mg L-1 of DMAC under optimal conditions. Finally, it can be concluded that the Electro- Fenton process was the best process for the efficient removal of DMSO and DMAC. The second step of the kinetic model follows a pseudo-first-order reaction for 250 and 500 mg L-1 of pollutants and obeyed a pseudo-second-order kinetic model for concentrations of 1000, 2000 mg L- 1.